Thermal Evaluation of Mass Pours (TEMP)

Thermal Evaluation of Mass Pours (TEMP)

Thermal Evaluation of Mass Pours (TEMP)

Thermal Wire® cables are fitted with custom-spaced temperature sensors. The copper cable is cast into the concrete, often tied to the reinforcement. Each Thermal Wire cable may include any number of sensors, and is connected to a single external TEMP data logger. TEMP data loggers read and store up to 28 days of temperature measurements and are powered by a replaceable battery. There are no batteries on the sensors themselves. Replacing the TEMP data logger battery makes it possible to monitor and store data indefinitely. Data is transferred from the TEMP data loggers to the TEMP main unit for observation, and then analyzed by the TEMP-S software. TEMP-S provides the user with graphs versus time of measured maximum temperatures and maximum differences in temperature (Delta). These are presented along with allowable limits. TEMP-S also calculates concrete maturity based on measured temperatures, and helps the user estimate concrete strength based on a user-determined strength-maturity relationship.
  • Highlights
  • Features
  • Specification
  • Models
  • Standards

Thermal Wire Concrete Temperature Monitoring System,Thermal Wire temperature sensors,  Concrete temperature monitoring system , Concrete maturity monitoring , TEMP data logger  Concrete strength estimation equipment , Mass concrete temperature monitoring,  Concrete thermal monitoring cables,  Concrete temperature data logger,  Concrete maturity testing equipment,  Temperature differential monitoring in concrete  ,TEMP-S software  ASTM C1074 concrete maturity method

Thermal Evaluation of Mass Pours (TEMP-Q) Specifications

19-335

PDF Format

TEMP-Q Data Logger

Size: 160 x 80 x 57 mm (6.3 x 3.2 x 2.2 in)
Weight: 540 g (1.2 lbs.)
Temperature Range: Operating -20° to 65° C (4º to 149º F); Storage -40° to 85° C (-40º to 185º F)
Contains 4 installed Li-Ion battery
Internal Battery (28-day duration)
Sampling frequency: user programmable, defaulted to once every 15 minutes
Contains 2 data acquisition ports
Hangs from reinforcement cage; may be bolted to cage for security
Water Resistant

TEMP-S Software

Furnished with a license for TEMP-S
Cloud based data retrieval

Thermal Wire® Cables

Custom ordered: each sensor comes standard with 3 m (10 ft) of cable
Sensor type: digital
Sensor operating temperature: maximum 105°C (32° F)

Other

Technical manual provided in PDF form on a USB drive.

Any question about the Thermal Evaluation of Mass Pours (TEMP) ?

* indicates required fields


QC LAB SOLUTION

  Usually Replies Instantly!

Hello! How Can We Help You Today? Choose a question below to chat with us on WhatsApp.

Chat on WhatsApp

QC Lab Solution